Hilti 3482514 Use and Care Manual Page 36

  • Download
  • Add to my manuals
  • Print
  • Page
    / 39
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 35
8.6 Checking the power tool after care and
maintenance
After carrying out care and maintenance work on
the power tool, check that all protective and safety
devices are fitted and that they function faultlessly.
9. Troubleshooting
Fault Possible cause Remedy
The power tool doesn’t run.
The battery is discharged or fitted
incorrectly.
The battery must be heard to engage
with a double click or, respectively,
needs to be charged.
Electrical fault. Remove the battery from the power
tool and contact Hilti Service.
The battery is too hot or too cold. Bring the battery to the recom-
mended working temperature.
The power tool doesn’t run
and 1 LED blinks.
The battery is discharged.
Change the battery and recharge the
discharged battery.
The battery is too hot or too cold. Bring the battery to the recom-
mended working temperature.
The power tool doesn’t run
and all 4 LEDs blink.
The power tool has been overloaded. Release the control switch and
press it again.
The overheating prevention cut-out
has been activated.
Allow the power tool to cool down.
Clean the ventilation slots.
No hammering action. The power tool is too cold. Allow the power tool to warm
up to the minimum operating
temperature.
See section: 7.2.1 Working at low
temperatures
The function selector switch is set
to “Drilling without hammering”.
Set the function selector switch to
“Hammer drilling”.
The forward/reverse switch is set to
reverse rotation.
Set the forward/reverse switch to
forward rotation.
The control switch can’t be
pressed, i.e. the switch is
locked.
The forward / reverse switch is in
the middle position (transport lock
engaged).
Push the forward / reverse switch
to the left or right.
The drive spindle doesn’t
rotate.
The permissible operating tempera-
ture of the power tool’s electronics
has been exceeded.
Allow the power tool to cool down.
The permissible battery operating
temperature has been exceeded.
Bring the battery to the recom-
mended working temperature.
The battery is discharged.
Change the battery and recharge the
discharged battery.
The power tool switches itself
off automatically.
The overload cut-out has been
activated.
Release the control switch, reduce
the load on the power tool and then
press the switch again.