Hilti 3493740 Use and Care Manual Page 16

  • Download
  • Add to my manuals
  • Print
  • Page
    / 19
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 15
Never operate the power tool when the ventilation
slots are blocked. Clean the ventilation slots carefully
using a dry brush. Do not permit foreign objects to
enter the interior of the power tool. Clean the outside
of the power tool at regular intervals with a slightly
damp cloth. Do not use a spray, steam pressure
cleaning equipment or running water for cleaning.
This may negatively affect the electrical safety of the
power tool.
8.3 Service indicator
NOTE
The power tool is equipped with a service indicator.
Indicator
Constant red light End of service interval - servicing is due. After the
lamp lights for the first time, the power tool may
continue to be used for several hours before the
automatic cut-out is activated. To ensure that the
power tool is always ready for use, it should be
returned to Hilti for servicing in good time.
Blinking red light
See section “Troubleshooting”.
8.4 Maintenance
WARNING
Repairs to the electrical section of the power tool
may be carried out only by trained electrical spe-
cialists.
Check all external parts of the power tool for damage
at regular intervals and check that all controls operate
faultlessly. Do not operate the power tool if parts
are damaged or when the controls do not function
faultlessly. If necessary, the power tool should be
repaired by Hilti Service.
8.5 Checking the power tool after care and
maintenance
After carrying out care and maintenance work on
the power tool, check that all protective and safety
devices are fitted and that they function faultlessly.
9. Troubleshooting
Fault Possible cause Remedy
The power tool doesn’t start.
Interruption in the electric supply. Plug in another electric appliance
and check whether it works.
The supply cord or plug is defective.
Have it checked by a trained
electrical specialist and replaced if
necessary.
Generator with sleep mode.
Apply a load to the generator by
connecting another appliance (e.g.
a lamp). Subsequently switch the
power tool off and on again.
Other electrical fault.
Have it checked by a trained
electrical specialist.
The electronic restart interlock is
activated after an interruption in the
electric supply.
Switch the power tool off and on
again.
The control switch is defective.
Have it checked by a trained
electrical specialist and replaced if
necessary.
en
29
Page view 15